AS 1418.12-1991 (R2016)
AS 1418.12-1991 (R2016)
Cranes (including hoists and winches) Crane collector systems
Standards Australia
Cranes (including hoists and winches) Crane collector systems
Standards Australia
<toc />
Specifies requirements for crane collector systems incorporating a sliding or rolling contact device. Does not cover direct-connected systems such as cable reelers or flexible cable systems.
RECONFIRMATION NOTICE
Technical Committee ME-005 has reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 1 November 2016.
The following are represented on Technical Committee ME-005:
Australian Chamber of Commerce and Industry
Australian Industry Group
Australian Institute for Non-Destructive Testing
Bureau of Steel Manufacturers of Australia
Concrete Pumping Association of Australia
Crane Association of New Zealand
Crane Industry Council of Australia
Department of Industry, Skills and Regional Development (NSW)
Department of Justice and Attorney General (QLD)
Electricity Engineers Association (New Zealand)
Engineers Australia
Institution of Professional Engineers New Zealand
SafeWork NSW
Transport for NSW
Worksafe Division, Department of Commerce, Western Australia
Worksafe New Zealand
WorkSafe Victoria
This Standard specifies requirements for crane collector systems incorporating a sliding or rolling contact device, referred to herein as 'CCS', intended for use on-
(a) alternating current systems, the rated voltage of which is greater than 32 V and does not exceed 1000 V, at frequencies from 25 Hz to 60 Hz; and
(b) direct current systems, the rated voltage of which is greater than 115 V and does not exceed 1500 V. The Standard does not cover direct-connected systems such as slip rings, cable reelers or flexible cable systems.
NOTES:
1 Guidance on the installation checks of CCS is provided in Appendix A.
2 Appendix B shows the typical components of a CCS, and cross-sections of enclosed CCS.