Categories

AS 3011.2-1992

AS 3011.2-1992

Electrical installations - Secondary batteries installed in buildings Sealed cells

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS 3011.2-1992 ELECTRICAL INSTALLATIONS-SECONDARY BATTERIES INSTALLED IN BUILDINGS - SEALED CELLS
4 -  PREFACE
4 -  CONTENTS
5 -  SECTION 1 SCOPE AND GENERAL
5 -  1.1 SCOPE
5 -  1.2 REFERENCED DOCUMENTS
5 -  1.3 DEFINITIONS
5 -  1.3.1 Accessible, readily
5 -  1.3.2 Authorized person
5 -  1.3.3 Battery
5 -  1.3.4 Battery enclosure
5 -  1.3.5 Battery room
5 -  1.3.6 Cell
5 -  1.3.7 Charging
5 -  1.3.8 Horizontally mounted cell
5 -  1.3.9 May
5 -  1.3.10 Monobloc battery
6 -  1.3.11 Nominal voltage
6 -  1.3.12 Sealed gastight cell
6 -  1.3.13 Sealed valve- regul ated cell
6 -  1.3.14 Shall
6 -  1.3.15 Should
6 -  1.3.16 Vertically mounted cell
7 -  SECTION 2 GENERAL REQUIREMENTS
7 -  2.1 GENERAL
7 -  2.1.1 Hydrogen emission
7 -  2.1.2 Alarms
7 -  2.1.3 Battery accommodation
7 -  2.1.4 Arrangement of cells
7 -  2.1.5 Ventilation
7 -  2.2 BATTERY ROOM REQUIREMENTS
7 -  2.2.1 General
7 -  2.2.2 Battery room layout and floor area
8 -  2.2.3 Take-off battery terminals and outgoing busbars and cables
8 -  2.2.4 Inter-tier and inter-row connections
8 -  2.2.5 Inter-cell connectors
8 -  2.2.6 Luminaires
8 -  2.2.7 Location of general purpose outlets
8 -  2.3 BATTERY ENCLOSURE REQUIREMENTS
8 -  2.3.1 Enclosure construction
8 -  2.3.2 Take-off battery terminals and outgoing busbars and cables
8 -  2.3.3 Battery compartment circuits
9 -  SECTION 3 INSTALLATION
9 -  3.1 GENERAL
9 -  3.2 CONNECTIONS
9 -  3.3 PROTECTION
9 -  3.3.1 Overcurrent protection
9 -  3.3.2 Warning notices
9 -  3.3.3 Switchgear
9 -  3.3.4 Earth-leakage detection
9 -  3.3.5 Main isolating switch
9 -  3.3.6 Section isolating equi pment
9 -  3.3.7 Fire safety and warning signs
10 -  APPENDIX A - TYPICAL BATTERY ROOM LAYOUT (SHOWING MINIMUM CLEARANCES)

Abstract

Specifies requirements for the installation of sealed secondary batteries permanently installed in buildings.

Scope

This Standard sets out requirements for the installation of sealed secondary batteries with a nominal voltage exceeding 24 V and a capacity exceeding 10 A.h at the 1 h rate of discharge, permanently installed in or on buildings, structures or premises to ensure safety from fire and electric shock. AS 2676.2 provides guidance on the installation and maintenance of sealed secondary batteries. This Standard covers sealed cells only. The installation and maintenance of vented cells are covered by AS 3011.1 and AS 2676.1.
NOTE: Requirements specifically applicable to the design and installation of extra-low voltage (d.c.) power supplies that are used by telecommunications carriers in the provision of public telecommunications networks are given in AS 3015 (Int)-1991, Electrical installations - Extra-low voltage (d.c.) power supplies in public telecommunications networks.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee EL-005
Supersedes
  • DR 90091

Contact us