AS 2325-1993 (R2013)
AS 2325-1993 (R2013)
Tungsten filament lamps for general service - Performance requirements
Standards Australia
Tungsten filament lamps for general service - Performance requirements
Standards Australia
Specifies performance requirements for incandescent lamps rated 25 W to 200 W with a voltage or voltage range of 100 V to 250 V and a nominal life of 1000 h, and a method to be used by manufacturers to show compliance with the requirements of the Standard. This Standard is identical with and has been reproduced from IEC 64:1987.
Technical Committee EL-041 has reviewed the content of this publication and in
accordance with Standards Australia procedures for reconfirmation, it has been determined
that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original
date of publication. Users are advised to ensure that they are using the latest versions of
such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for
reconfirmation on 22 July 2013.
The following are represented on Technical Committee EL-041:
Australasian Fire and Emergency Service Authorities Council
Australian Industry Group
Certification Interests, New Zealand
Consumers Federation of Australia
Department of Climate Change and Energy Efficiency
Electrical Compliance Testing Association
Electrical Regulatory Authorities Council
Energy Efficiency and Conservation Authority of New Zealand
Fair Trading NSW
IES: The Lighting Society
Institution of Professional Engineers New Zealand
International Accreditation New Zealand
Lighting Council Australia
Lighting Council New Zealand
New Zealand Ministry of Business, Innovation and Employment
New Zealand Lighting Manufacturers and Suppliers
This standard applies to incandescent lamps for general lighting service which comply with the requirements in IEC Publication 432: Safety Requirements for Tungsten Filament Lamps for Domestic and Similar General Lighting Purposes, and having:
- a nominal life of 1000 h,
- a rated wattage of 25 W to 200 W, inclusive,
- a rated voltage of 100 V to 250 V, inclusive (if marked with a voltage range, not exceeding ±2.5% of the mean voltage),
Note. - In countries in the process of changing from 220 V to 230 V nominal supply voltage, a range of ±3.5% is temporarily accepted.
- bulbs pear shaped or mushroom shaped, - bulbs finished clear or internally frosted, - caps B22d or E27 as set out in Appendix A.
Requirements for batch testing are included to facilitate the assessment of individual batches. Batch testing cannot be used for certification purposes.