AS 4260-1997 (R2018)
AS 4260-1997 (R2018)
High efficiency particulate air (HEPA) filters - Classification, construction and performance
Standards Australia
High efficiency particulate air (HEPA) filters - Classification, construction and performance
Standards Australia
Specifies requirements for the classification, construction and performance testing of fully disposable high efficiency particulate air (HEPA) filters. It includes those filters known as ultra low penetration air (ULPA) filters but excludes medium efficiency particulate air filters (MEPA). An appendix provides requirements for structural strength testing.
RECONFIRMATION NOTICE
Major stakeholders of this publication have reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 29 August 2018.
This Standard specifies requirements for the classification, construction and performance testing of fully disposable high efficiency particulate air (HEPA) filters. It includes those filters known as ultra low penetration air (ULPA) filters but excludes medium efficiency particulate air filters (MEPA).
NOTES:
1 Requirements for air filters for use in general ventilation and airconditioning are given in AS 1324.1 and AS 1324.2. Although MEPA filters are not within the scope of this Standard it is recognized that there are similarities of construction, and relevant parts of this Standard may be applied to MEPA filters by buyer/seller agreement.
2 The filters covered by this Standard achieve very low sub-micrometre particulate levels for the protection of people, products, and processes from potential contamination. Common applications are cleanrooms for control and protection of pharmaceutical and electronic processes, operating theatres, clean workstations, nuclear containment facilities, and biological containment facilities including safety cabinets.
3 Purchasing guidelines are provided in Appendix A. Handling and shipment guidelines are provided in Appendix B.
Document Type | Standard |
Status | Current |
Publisher | Standards Australia |
ProductNote | Reconfirmed 14/09/2018. This standard has been reconfirmed in Australia in 2018 and remains current in New Zealand. Reconfirmation Notice 14/09/2018 |
Committee | ME-080 |
Supersedes |
|