Categories

AS 1603.14-2001

AS 1603.14-2001

Automatic fire detection and alarm systems Point type carbon monoxide (CO) fire detectors

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

<toc>
<bookmarktable>
<bookmark index='0'>
<pageno>1</pageno>
<text>AS 1603.14-2001 AUTOMATIC FIRE DETECTION AND ALARM SYSTEMS - POINT TYPE CARBON MONOXIDE (CO) FIRE DETECTORS</text>
<bookmark index='1'>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index='2'>
<pageno>5</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index='3'>
<pageno>6</pageno>
<text>SECTION 1 SCOPE AND GENERAL</text>
<bookmark index='4'>
<pageno>6</pageno>
<text>1.1 SCOPE</text>
</bookmark>
<bookmark index='5'>
<pageno>6</pageno>
<text>1.2 APPLICATION</text>
</bookmark>
<bookmark index='6'>
<pageno>6</pageno>
<text>1.3 REFERENCED DOCUMENTS</text>
</bookmark>
<bookmark index='7'>
<pageno>7</pageno>
<text>1.4 DEFINITIONS</text>
<bookmark index='8'>
<pageno>7</pageno>
<text>1.4.1 Alarm state</text>
</bookmark>
<bookmark index='9'>
<pageno>7</pageno>
<text>1.4.2 Alarm response threshold (ART)</text>
</bookmark>
<bookmark index='10'>
<pageno>7</pageno>
<text>1.4.3 Sensing assembly</text>
</bookmark>
</bookmark>
<bookmark index='11'>
<pageno>7</pageno>
<text>1.5 INTERPRETATION OF SPECIFIED LIMITING VALUES</text>
</bookmark>
</bookmark>
<bookmark index='12'>
<pageno>8</pageno>
<text>SECTION 2 FUNCTIONS</text>
<bookmark index='13'>
<pageno>8</pageno>
<text>2.1 GENERAL</text>
</bookmark>
<bookmark index='14'>
<pageno>8</pageno>
<text>2.2 ALARM RESPONSE THRESHOLD (ART)</text>
</bookmark>
<bookmark index='15'>
<pageno>8</pageno>
<text>2.3 ALARM RESPONSE THRESHOLD (ART) ADJUSTMENTS</text>
</bookmark>
<bookmark index='16'>
<pageno>8</pageno>
<text>2.4 PROLONGED EXPOSURE</text>
</bookmark>
<bookmark index='17'>
<pageno>8</pageno>
<text>2.5 CROSS SENSITIVITY</text>
</bookmark>
</bookmark>
<bookmark index='18'>
<pageno>10</pageno>
<text>SECTION 3 DESIGN AND CONSTRUCTION</text>
<bookmark index='19'>
<pageno>10</pageno>
<text>3.1 GENERAL</text>
</bookmark>
<bookmark index='20'>
<pageno>10</pageno>
<text>3.2 MATERIALS AND COMPONENTS</text>
<bookmark index='21'>
<pageno>10</pageno>
<text>3.2.1 Resistance to corrosion</text>
</bookmark>
<bookmark index='22'>
<pageno>10</pageno>
<text>3.2.2 Resistance to high temperatures</text>
</bookmark>
</bookmark>
<bookmark index='23'>
<pageno>11</pageno>
<text>3.3 ELECTRICAL</text>
<bookmark index='24'>
<pageno>11</pageno>
<text>3.3.1 Electrical safety</text>
</bookmark>
<bookmark index='25'>
<pageno>11</pageno>
<text>3.3.2 Printed circuit boards</text>
</bookmark>
</bookmark>
<bookmark index='26'>
<pageno>11</pageno>
<text>3.4 CONNECTING FACILITIES</text>
</bookmark>
<bookmark index='27'>
<pageno>11</pageno>
<text>3.5 INDICATING FACILITIES</text>
</bookmark>
<bookmark index='28'>
<pageno>11</pageno>
<text>3.6 ENCLOSURES</text>
</bookmark>
<bookmark index='29'>
<pageno>11</pageno>
<text>3.7 MOUNTING FACILITIES</text>
</bookmark>
</bookmark>
<bookmark index='30'>
<pageno>12</pageno>
<text>SECTION 4 PRODUCT INFORMATION AND MARKING</text>
<bookmark index='31'>
<pageno>12</pageno>
<text>4.1 MARKING</text>
</bookmark>
<bookmark index='32'>
<pageno>12</pageno>
<text>4.2 POINT OF SALE INFORMATION</text>
</bookmark>
</bookmark>
<bookmark index='33'>
<pageno>13</pageno>
<text>SECTION 5 ASSESSMENT OF COMPLIANCE</text>
<bookmark index='34'>
<pageno>13</pageno>
<text>5.1 CRITERIA OF ASSESSMENT AND TEST SCHEDULE</text>
<bookmark index='35'>
<pageno>13</pageno>
<text>5.1.1 Information required for assessment</text>
</bookmark>
<bookmark index='36'>
<pageno>13</pageno>
<text>5.1.2 Environmental conditions</text>
</bookmark>
<bookmark index='37'>
<pageno>13</pageno>
<text>5.1.3 Test schedule</text>
</bookmark>
<bookmark index='38'>
<pageno>13</pageno>
<text>5.1.4 Test failure</text>
</bookmark>
</bookmark>
<bookmark index='39'>
<pageno>13</pageno>
<text>5.2 FUNCTIONAL ASSESSMENT</text>
<bookmark index='40'>
<pageno>13</pageno>
<text>5.2.1 Strength of screw threads and fixings</text>
</bookmark>
<bookmark index='41'>
<pageno>15</pageno>
<text>5.2.2 Alarm verification delay (AVD)</text>
</bookmark>
<bookmark index='42'>
<pageno>15</pageno>
<text>5.2.3 Operational test</text>
</bookmark>
</bookmark>
<bookmark index='43'>
<pageno>15</pageno>
<text>5.3 ENDURANCE ASSESSMENT</text>
<bookmark index='44'>
<pageno>15</pageno>
<text>5.3.1 Voltage stability</text>
</bookmark>
<bookmark index='45'>
<pageno>15</pageno>
<text>5.3.2 Insulation resistance</text>
</bookmark>
<bookmark index='46'>
<pageno>15</pageno>
<text>5.3.3 Static discharge</text>
</bookmark>
<bookmark index='47'>
<pageno>15</pageno>
<text>5.3.4 Electromagnetic interference</text>
</bookmark>
<bookmark index='48'>
<pageno>15</pageno>
<text>5.3.5 Impulse voltage withstand</text>
</bookmark>
<bookmark index='49'>
<pageno>15</pageno>
<text>5.3.6 High-frequency disturbance</text>
</bookmark>
<bookmark index='50'>
<pageno>16</pageno>
<text>5.3.7 Compatibility parameters</text>
</bookmark>
<bookmark index='51'>
<pageno>16</pageno>
<text>5.3.8 Low temperature</text>
</bookmark>
<bookmark index='52'>
<pageno>16</pageno>
<text>5.3.9 Damp heat</text>
</bookmark>
<bookmark index='53'>
<pageno>16</pageno>
<text>5.3.10 Dry heat</text>
</bookmark>
<bookmark index='54'>
<pageno>16</pageno>
<text>5.3.11 Vibration</text>
</bookmark>
<bookmark index='55'>
<pageno>16</pageno>
<text>5.3.12 Corrosion</text>
</bookmark>
<bookmark index='56'>
<pageno>16</pageno>
<text>5.3.13 Air velocity stability</text>
</bookmark>
<bookmark index='57'>
<pageno>16</pageno>
<text>5.3.14 Impact</text>
</bookmark>
<bookmark index='58'>
<pageno>16</pageno>
<text>5.3.15 Dust</text>
</bookmark>
</bookmark>
<bookmark index='59'>
<pageno>16</pageno>
<text>5.4 REPORTING</text>
</bookmark>
</bookmark>
</bookmark>
</bookmarktable>
</toc>

Abstract

Specifies requirements for the design, construction and performance of carbon monoxide fire detectors.

Scope

This Standard specifies requirements for the design, construction and performance of point type carbon monoxide (CO) fire detectors as used in fire detection, warning, control and intercom systems.
This Standard does not cover detectors installed in air handling ducts, although many provisions herein could be applied to such applications.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee FP-002
Supersedes
  • DR 99327
Superseded By
  • AS 7240.6-2006 (R2016)

Contact us