AS/NZS 3823.3:2002 (R2014)

AS/NZS 3823.3:2002 (R2014)

Performance of electrical appliances - Airconditioners and heat pumps Calculation of performance for minimum energy performance standard (MEPS) requirements

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS/NZS 3823.3:2002 PERFORMANCE OF ELECTRICAL APPLIANCES-AIRCONDITIONERS AND HEAT PUMPS - CALCULATION OF PERFORMANCE FOR MINIM
4 -  PREFACE
5 -  CONTENTS
6 -  SECTION 1 SCOPE AND GENERAL
6 -  1.1 SCOPE
6 -  1.2 OBJECTIVE
7 -  1.3 APPLICATION
7 -  1.4 REFERENCED DOCUMENTS
7 -  1.5 DEFINITIONS
7 -  1.6 SIMULATION MODEL
7 -  1.6.1 General
7 -  1.6.2 Measurement of appliance operating conditions
7 -  1.6.3 Matching the modelled refrigerant circuit
8 -  1.6.4 Measured data
8 -  1.6.5 Corrections to compressor performance
9 -  SECTION 2 MEASUREMENT OF APPLIANCE CHARACTERISTICS
9 -  2.1 SCOPE
9 -  2.2 TEST CONDITIONS
9 -  2.3 MEASUREMENT OF REFRIGERANT CIRCUIT PRESSURE DROP (OPTIONAL)
9 -  2.3.1 General
9 -  2.3.2 Default pressure drop conditions
9 -  2.4 MEASUREMENT OF REFRIGERANT CIRCUIT SET POINT CONDITIONS (OPTIONAL)
9 -  2.4.1 General
9 -  2.4.2 Default refrigerant circuit set point conditions
10 -  2.5 AIRFLOW RATE THROUGH THE COILS
10 -  2.5.1 Non-ducted appliances
10 -  2.5.2 Ducted appliances
10 -  2.6 COMPRESSOR CHARACTERISTICS
10 -  2.7 ELECTRICAL POWER CONSUMPTION
10 -  2.7.1 Power consumption of compressor
10 -  2.7.2 Power consumption of fans
11 -  2.7.3 Power consumption of other electrical components
11 -  2.8 COIL CHARACTERISTICS
12 -  SECTION 3 PERFORMANCE ANALYSIS
12 -  3.1 REQUIRED SIMULATION MODEL FEATURES
12 -  3.2 MODEL CHARACTERISTICS
12 -  3.2.1 General
12 -  3.2.2 Correlation models
13 -  3.2.3 Lumped component models
13 -  3.2.4 Simulation models
13 -  3.2.5 Simulation models with specified refrigerant operating states
14 -  APPENDIX A - FORMAT SHEETS FOR RECORDING REFRIGERANT CIRCUIT OPERATING CONDITIONS OR ACCEPTANCE OF DEFAULT CONDITIONS
14 -  A1 PRESSURE DROP ACROSS HIGH- AND LOW-PRESSURE SIDES OF THE REFRIGERANT CIRCUIT
14 -  A1.1 General
14 -  A1.2 Test conditions - Cooling
15 -  A1.3 Test results - Cooling
15 -  A1.4 Test conditions - Heating (if applicable)
15 -  A1.5 Test results - Heating (if applicable)
16 -  A1.6 Default pressure drop conditions
16 -  A2 REFRIGERANT CIRCUIT SET POINT CONDITIONS
16 -  A2.1 General
16 -  A2.2 Test conditions - Cooling
17 -  A2.3 Test results - Cooling
17 -  A2.4 Test conditions - Heating (if applicable)
18 -  A2.5 Test results - Heating (if applicable)
18 -  A2.6 Default refrigerant circuit set point conditions
19 -  APPENDIX B - FORMAT SHEETS FOR APPLIANCE DEFINITION
24 -  APPENDIX C - THE OAK RIDGE HEAT PUMP MODEL
26 -  APPENDIX D - CALCULATION OF HEAT LOSS/GAIN FROM REFRIGERANT LINES

Abstract

Specifies procedures for calculating the performance of factory-made residential, commercial and industrial, electrically driven, mechanical compression, single-package and split-system, ducted and non-ducted airconditioners for determining their compliance with minimum energy performance standard (MEPS) requirements specified in AS/NZS 3823.2.

RECONFIRMATION NOTICE
Technical Committee EL-056 has reviewed the content of this publication and in
accordance with Standards Australia procedures for reconfirmation, it has been determined
that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original
date of publication. Users are advised to ensure that they are using the latest versions of
such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for
reconfirmation on 24 October 2013.
Approved for reconfirmation in New Zealand on behalf of the Standards Council of New
Zealand on 29 May 2013.
The following are represented on Technical Committee EL-056:
Airconditioning and Refrigeration Equipment Manufacturers Association of Australia
Australian Building Codes Board
Australian Industry Group
CHOICE
Consumer Electronics Association of New Zealand
Consumer Electronics Suppliers Association
Department of Climate Change and Energy Efficiency
Electrical Compliance Testing Association
Energy Efficiency and Conservation Authority of New Zealand
Energy Safe Victoria
Institute of Refrigeration Heating and AirConditioning Engineers of New Zealand
Institution of Professional Engineers New Zealand
NSW Department of Trade and Investment, Regional Infrastructure and Services
Office of the Technical Regulator SA
The University of New South Wales

Scope

This Standard specifies procedures for calculating the performance of factory-made residential, commercial and industrial, electrically-driven, mechanical compression, single-package and split-system, ducted and non-ducted airconditioners and heat pumps employing air- and water-cooled condensers. This Standard covers equipment utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units controlled by a single thermostat/controller. This Standard covers equipment utilizing single, multiple and variable capacity components.
NOTE: The method in this Standard includes a combination of measured component performance, equipment operating conditions and a mathematical model to determine the appliance performance.
This Standard does not cover single circuit multiple compressor units.
This Standard can be used to quantify the following values for cooling and heating:
(a) Rated cooling capacity.
(b) Rated heating capacity.
(c) Energy efficiency ratio (EER).
(d) Coefficient of performance (COP).
This Standard does not apply to the rating of the following:
(i) Water-source heat pumps.
(ii) Multi-split airconditioners and heat pumps.
(iii) Mobile appliances having a condenser exhaust duct.
(iv) Unitary systems where there is a thermal interaction between the evaporator and condenser.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 23/05/2014.
This standard has been reconfirmed in Australia in 2014 and remains current in New Zealand.
Reconfirmation Notice 23/05/2014
Committee EL-015
Supersedes
  • AS/NZS 3823.3:2001
  • DR 01398-01401 CP
  • DR 01401 CP

Contact us