Categories

AS/NZS 61558.2.5:2003

AS/NZS 61558.2.5:2003

Safety of power transformers, power supply units and similar devices Particular requirements for shaver transformers (IEC 61558-2-5:1997, MOD)

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

<toc>
<bookmarktable>
<bookmark index=&apos;0&apos;>
<pageno>1</pageno>
<text>AS/NZS 61558.2.5:2003 SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR - PARTICULAR REQUIREMENTS FOR SHAVER TRANS</text>
<bookmark index=&apos;1&apos;>
<pageno>4</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index=&apos;2&apos;>
<pageno>5</pageno>
<text>FOREWORD</text>
</bookmark>
<bookmark index=&apos;3&apos;>
<pageno>7</pageno>
<text>1 Scope</text>
</bookmark>
<bookmark index=&apos;4&apos;>
<pageno>7</pageno>
<text>2 Normative references</text>
</bookmark>
<bookmark index=&apos;5&apos;>
<pageno>8</pageno>
<text>3 Definitions</text>
</bookmark>
<bookmark index=&apos;6&apos;>
<pageno>8</pageno>
<text>4 General requirements</text>
</bookmark>
<bookmark index=&apos;7&apos;>
<pageno>8</pageno>
<text>5 General notes on tests</text>
</bookmark>
<bookmark index=&apos;8&apos;>
<pageno>8</pageno>
<text>6 Ratings</text>
</bookmark>
<bookmark index=&apos;9&apos;>
<pageno>9</pageno>
<text>7 Classification</text>
</bookmark>
<bookmark index=&apos;10&apos;>
<pageno>9</pageno>
<text>8 Marking and other information</text>
</bookmark>
<bookmark index=&apos;11&apos;>
<pageno>10</pageno>
<text>9 Protection against accessibility to hazardous live parts</text>
</bookmark>
<bookmark index=&apos;12&apos;>
<pageno>10</pageno>
<text>10 Change of input voltage setting</text>
</bookmark>
<bookmark index=&apos;13&apos;>
<pageno>10</pageno>
<text>11 Output voltage and output current under load</text>
</bookmark>
<bookmark index=&apos;14&apos;>
<pageno>10</pageno>
<text>12 No-load output voltage</text>
</bookmark>
<bookmark index=&apos;15&apos;>
<pageno>11</pageno>
<text>13 Short circuit voltage</text>
</bookmark>
<bookmark index=&apos;16&apos;>
<pageno>11</pageno>
<text>14 Heating</text>
</bookmark>
<bookmark index=&apos;17&apos;>
<pageno>11</pageno>
<text>15 Short-circuit and overload protection</text>
</bookmark>
<bookmark index=&apos;18&apos;>
<pageno>11</pageno>
<text>16 Mechanical strength</text>
</bookmark>
<bookmark index=&apos;19&apos;>
<pageno>12</pageno>
<text>17 Protection against harmful ingress of dust, solid objects and moisture</text>
</bookmark>
<bookmark index=&apos;20&apos;>
<pageno>12</pageno>
<text>18 Insulation resistance and dielectric strength</text>
</bookmark>
<bookmark index=&apos;21&apos;>
<pageno>13</pageno>
<text>19 Construction</text>
</bookmark>
<bookmark index=&apos;22&apos;>
<pageno>14</pageno>
<text>20 Components</text>
</bookmark>
<bookmark index=&apos;23&apos;>
<pageno>15</pageno>
<text>21 Internal wiring</text>
</bookmark>
<bookmark index=&apos;24&apos;>
<pageno>15</pageno>
<text>22 Supply connection and other external flexible cables or cords</text>
</bookmark>
<bookmark index=&apos;25&apos;>
<pageno>15</pageno>
<text>23 Terminals for external conductors</text>
</bookmark>
<bookmark index=&apos;26&apos;>
<pageno>15</pageno>
<text>24 Provision for protective earthing</text>
</bookmark>
<bookmark index=&apos;27&apos;>
<pageno>15</pageno>
<text>25 Screws and connections</text>
</bookmark>
<bookmark index=&apos;28&apos;>
<pageno>15</pageno>
<text>26 Creepage distances, clearances and distances through insulation</text>
</bookmark>
<bookmark index=&apos;29&apos;>
<pageno>15</pageno>
<text>27 Resistance to heat, abnormal heat, fire and tracking</text>
</bookmark>
<bookmark index=&apos;30&apos;>
<pageno>15</pageno>
<text>28 Resistance to rusting</text>
</bookmark>
<bookmark index=&apos;31&apos;>
<pageno>16</pageno>
<text>Annexes</text>
</bookmark>
<bookmark index=&apos;32&apos;>
<pageno>17</pageno>
<text>Annex ZZ - Variations to IEC 61558-2-5:1997 for application in Australia and New Zealand</text>
</bookmark>
</bookmark>
</bookmarktable>
</toc>

Abstract

Specifies general safety requirements for approval and test purposes for shaver transformers. This Standard is an adoption with national modifications and contains the full text of IEC 61558-2-5:1997.

Scope

Replacement:
This part 2-5 of IEC 61558 applies to shaver supply units, embodying one or more socket-outlets and a single phase air cooled isolating transformer, having a rated supply voltage not exceeding 250 V a.c., a rated output not less than 20 VA and not exceeding 50 VA, a rated output voltage not exceeding 250 V, and a rated frequency not exceeding 500 Hz.
This standard is also applicable to shaver transformers for embodiment into shaver supply units.
NOTE 1 Shaver supply units may be flush or surface mounted or incorporated in luminaires and other equipment. NOTE 2 Shaver supply units may be used to supply shavers, tooth brushes and similar small power devices.
This part 2-5 of IEC 61558 applies to shaver transformers for embodiment into shaver supply units. These transformers are single phase air cooled isolating transformers, having a rated supply voltage not exceeding 250 V a.c., a rated output not less than 20 VA and not exceeding 50 VA, a rated output voltage not exceeding 250 V, and a rated frequency not exceeding 500 Hz.
NOTE 301 Requirements for shaver supply units are contained in AS/NZS 3194.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee EL-002
Under Revision
  • DR 10918 CP
Supersedes
  • AS/NZS 3108:1994
  • DR 01943 CP
Superseded By
  • AS/NZS 61558.2.5:2011 (IEC TEXT)
  • AS/NZS 61558.2.5:2011
  • AS/NZS 61558.2.5:2011

Contact us