Categories

AS 7240.12-2007

AS 7240.12-2007

Fire detection and alarm systems Line type smoke detectors using a transmitted optical beam

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS 7240.12-2007 Fire detection and alarm systems Part 12: Line type smoke detectors using a transmitted optical beam
4 -  PREFACE
5 -  CONTENTS
7 -  Introduction
9 -  1 Scope
9 -  2 Normative references
10 -  3 Terms and definitions
11 -  4 General requirements
11 -  4.1 Compliance
11 -  4.2 Individual alarm indication
11 -  4.3 Connection of ancillary devices
11 -  4.4 Monitoring of detachable detectors and connections
11 -  4.5 Manufacturer’s adjustments
11 -  4.6 On-site adjustment of response threshold value
12 -  4.7 Protection of optical components
12 -  4.8 Limit of compensation
12 -  4.9 Marking
12 -  4.10 Data
13 -  4.11 Requirements for software controlled detectors
14 -  4.12 Fault signalling
14 -  5 Test methods
14 -  5.1 General
16 -  5.2 Reproducibility
17 -  5.3 Repeatability
18 -  5.4 Directional dependence
19 -  5.5 Variation of supply parameters
19 -  5.6 Rapid changes in attenuation
20 -  5.7 Slow changes in attenuation
20 -  5.8 Optical path length dependence
21 -  5.9 Fire sensitivity
23 -  5.10 Stray light
24 -  5.11 Dry heat (operational)
25 -  5.12 Cold (operational)
26 -  5.13 Damp heat, steady state (operational)
27 -  5.14 Damp heat, steady state (endurance)
27 -  5.15 Vibration, sinusoidal (endurance)
28 -  5.16 Electromagnetic compatibility (EMC), immunity tests (operational)
29 -  5.17 Sulfur dioxide, SO2, corrosion (endurance)
30 -  5.18 Impact (operational)
31 -  6 Test report
32 -  Annex A (informative) Compensation for detector drift
37 -  Annex B (normative) Bench for response threshold value measurements
39 -  Annex C (normative) Fire test room
41 -  Annex D (normative) Smouldering pyrolysis wood fire (TF2)
43 -  Annex E (normative) Glowing smouldering cotton fire (TF3)
45 -  Annex F (normative) Flaming plastics (polyurethane) fire (TF4)
47 -  Annex G (normative) Flaming liquid (n-heptane) fire (TF5)
48 -  Annex H (normative) Smoke-measuring instruments
51 -  Annex I (normative) Apparatus for stray light
53 -  Annex J (informative) Information concerning the construction of the measuring ionization chamber

Abstract

Specifies requirements, test methods and performance criteria for line type smoke detectors utilizing the attenuation and/or changes in attenuation of an optical beam, for use in fire detection systems installed in buildings.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee FP-002
Under Revision
  • DR AS 7240.12:2018
Supersedes
  • DR 05186
Superseded By
  • AS 7240.12:2018

Contact us