AS/NZS 3191:2008
AS/NZS 3191:2008
Electric flexible cords
Standards Australia
<toc>
<bookmarktable>
<bookmark index='0'>
<pageno>1</pageno>
<text>AS/NZS 3191:2008 ELECTRIC FLEXIBLE CORDS</text>
<bookmark index='1'>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index='2'>
<pageno>5</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index='3'>
<pageno>6</pageno>
<text>SECTION 1 SCOPE AND APPLICATION</text>
<bookmark index='4'>
<pageno>6</pageno>
<text>1.1 SCOPE</text>
</bookmark>
<bookmark index='5'>
<pageno>6</pageno>
<text>1.2 REFERENCED DOCUMENTS</text>
</bookmark>
<bookmark index='6'>
<pageno>7</pageno>
<text>1.3 DEFINITIONS</text>
<bookmark index='7'>
<pageno>7</pageno>
<text>1.3.1 Approximate value</text>
</bookmark>
<bookmark index='8'>
<pageno>7</pageno>
<text>1.3.2 Core</text>
</bookmark>
<bookmark index='9'>
<pageno>7</pageno>
<text>1.3.3 Direction of lay</text>
</bookmark>
<bookmark index='10'>
<pageno>7</pageno>
<text>1.3.4 Flexible cord</text>
</bookmark>
<bookmark index='11'>
<pageno>7</pageno>
<text>1.3.5 Multicore cord</text>
</bookmark>
<bookmark index='12'>
<pageno>7</pageno>
<text>1.3.6 Pitch circle diameter</text>
</bookmark>
<bookmark index='13'>
<pageno>8</pageno>
<text>1.3.7 Routine tests</text>
</bookmark>
<bookmark index='14'>
<pageno>8</pageno>
<text>1.3.8 Sample tests</text>
</bookmark>
<bookmark index='15'>
<pageno>8</pageno>
<text>1.3.9 Type tests</text>
</bookmark>
<bookmark index='16'>
<pageno>8</pageno>
<text>1.3.10 Voltage designation</text>
</bookmark>
</bookmark>
<bookmark index='17'>
<pageno>8</pageno>
<text>1.4 VOLTAGE DESIGNATION AND DUTY RATING</text>
</bookmark>
</bookmark>
<bookmark index='18'>
<pageno>9</pageno>
<text>SECTION 2 CONSTRUCTION</text>
<bookmark index='19'>
<pageno>9</pageno>
<text>2.1 CONDUCTORS</text>
</bookmark>
<bookmark index='20'>
<pageno>9</pageno>
<text>2.2 INSULATION</text>
<bookmark index='21'>
<pageno>9</pageno>
<text>2.2.1 Material</text>
</bookmark>
<bookmark index='22'>
<pageno>9</pageno>
<text>2.2.2 Application</text>
</bookmark>
<bookmark index='23'>
<pageno>9</pageno>
<text>2.2.3 Thickness</text>
</bookmark>
<bookmark index='24'>
<pageno>13</pageno>
<text>2.2.4 Core identification</text>
</bookmark>
</bookmark>
<bookmark index='25'>
<pageno>13</pageno>
<text>2.3 LAY-UP OF CORES</text>
</bookmark>
<bookmark index='26'>
<pageno>13</pageno>
<text>2.4 FILLERS AND BINDERS</text>
</bookmark>
<bookmark index='27'>
<pageno>14</pageno>
<text>2.5 SCREENS</text>
</bookmark>
<bookmark index='28'>
<pageno>14</pageno>
<text>2.6 SHEATH</text>
<bookmark index='29'>
<pageno>14</pageno>
<text>2.6.1 Material</text>
</bookmark>
<bookmark index='30'>
<pageno>14</pageno>
<text>2.6.2 Application</text>
</bookmark>
<bookmark index='31'>
<pageno>15</pageno>
<text>2.6.3 Thickness</text>
</bookmark>
<bookmark index='32'>
<pageno>15</pageno>
<text>2.6.4 Colour</text>
</bookmark>
</bookmark>
<bookmark index='33'>
<pageno>15</pageno>
<text>2.7 NON-METALLIC BRAID</text>
</bookmark>
<bookmark index='34'>
<pageno>15</pageno>
<text>2.8 MARKING</text>
<bookmark index='35'>
<pageno>15</pageno>
<text>2.8.1 Information to be marked</text>
</bookmark>
<bookmark index='36'>
<pageno>15</pageno>
<text>2.8.2 Means of marking</text>
</bookmark>
<bookmark index='37'>
<pageno>16</pageno>
<text>2.8.3 Marking of packaging</text>
</bookmark>
</bookmark>
<bookmark index='38'>
<pageno>16</pageno>
<text>2.9 TESTS</text>
</bookmark>
<bookmark index='39'>
<pageno>18</pageno>
<text>2.10 CONSTRUCTION</text>
<bookmark index='40'>
<pageno>18</pageno>
<text>2.10.1 General</text>
</bookmark>
<bookmark index='41'>
<pageno>18</pageno>
<text>2.10.2 Construction of 250/250 V light duty, cross-linked elastomer insulated, unsheathed single-core flexible cords</text>
</bookmark>
<bookmark index='42'>
<pageno>18</pageno>
<text>2.10.3 Construction of 250/250 V light duty, thermoplastic PVC insulated, unsheathed, parallel-webbed 2-core flat...</text>
</bookmark>
<bookmark index='43'>
<pageno>18</pageno>
<text>2.10.4 Construction of 250/250 V light duty, cross-linked or thermoplastic PVC insulated and sheathed, 2-core flat, and...</text>
</bookmark>
<bookmark index='44'>
<pageno>18</pageno>
<text>2.10.5 Construction of 250/250 V light duty, cross-linked elastomer or cross-linked PVC insulated, textile braided 2...</text>
</bookmark>
<bookmark index='45'>
<pageno>18</pageno>
<text>2.10.6 Construction of 250/250 V light duty, R-S-150 cross-linked elastomer insulated, glass fibre braided, single-, 2...</text>
</bookmark>
<bookmark index='46'>
<pageno>19</pageno>
<text>2.10.7 Construction of 250/440 V ordinary duty, thermoplastic PVC insulated, unsheathed single-core flexible cords</text>
</bookmark>
<bookmark index='47'>
<pageno>19</pageno>
<text>2.10.8 Construction of 250/440 V ordinary duty, thermoplastic or cross-linked PVC insulated and sheathed, 2-core flat...</text>
</bookmark>
<bookmark index='48'>
<pageno>19</pageno>
<text>2.10.9 Construction of 250/440 V ordinary duty, thermoplastic or cross-linked PVC and cross-linked elastomer insulated...</text>
</bookmark>
<bookmark index='49'>
<pageno>19</pageno>
<text>2.10.10 Construction of 250/440 V ordinary duty, R°S°150 cross°linked elastomer insulated and GP°150°S sheathed 2- and 3...</text>
</bookmark>
<bookmark index='50'>
<pageno>19</pageno>
<text>2.10.11 Construction of 250/440 V ordinary duty, thermoplastic or cross-linked PVC or cross-linked elastomer insulated...</text>
</bookmark>
<bookmark index='51'>
<pageno>19</pageno>
<text>2.10.12 Construction of 0.6/1 kV heavy duty, thermoplastic PVC insulated, unsheathed single-core flexible cords</text>
</bookmark>
<bookmark index='52'>
<pageno>20</pageno>
<text>2.10.13 Construction of 0.6/1 kV heavy duty, thermoplastic PVC, cross-linked polyolefin or cross-linked elastomer...</text>
</bookmark>
</bookmark>
</bookmark>
<bookmark index='53'>
<pageno>21</pageno>
<text>APPENDIX A - PURCHASING GUIDELINES</text>
</bookmark>
<bookmark index='54'>
<pageno>22</pageno>
<text>APPENDIX B - AS/NZS 3191 REPLACEMENT CORDS FOR IEC CORDS</text>
</bookmark>
<bookmark index='55'>
<pageno>23</pageno>
<text>APPENDIX C - TEST FOR RESISTANCE TO HEAT OF TEXTILE BRAIDS</text>
<bookmark index='56'>
<pageno>23</pageno>
<text>C1 GENERAL</text>
</bookmark>
<bookmark index='57'>
<pageno>23</pageno>
<text>C2 APPARATUS</text>
</bookmark>
<bookmark index='58'>
<pageno>23</pageno>
<text>C3 SAMPLE</text>
</bookmark>
<bookmark index='59'>
<pageno>23</pageno>
<text>C4 PREPARATION</text>
</bookmark>
<bookmark index='60'>
<pageno>23</pageno>
<text>C5 TEST PROCEDURE</text>
</bookmark>
<bookmark index='61'>
<pageno>23</pageno>
<text>C6 CRITERIA</text>
</bookmark>
</bookmark>
</bookmark>
</bookmarktable>
</toc>
Specifies construction, dimensions and tests for flexible cords insulated with thermoplastic or cross-linked PVC, cross-linked elastomers, or cross-linked polyolefin which, dependent on cord type, are designed for working voltages up to and including 250/250 V, 250/440 V or 0.6/1 kV.
This Standard specifies construction, dimensions and tests for flexible cords insulated with thermoplastic or cross-linked PVC, cross-linked elastomers, or cross-linked polyolefin which, dependent on cord type, are designed for working voltages up to and including 250/250 V, 250/440 V or 0.6/1 kV. Compliance with this Standard does not necessarily imply suitability for end use. End applications need to be considered to ensure appropriate cord selection.
NOTES:
1 This Standard is intended to apply only to flexible cords of the types and sizes which are included. It is not intended, however, that other types or sizes of flexible cord should be precluded from use, and regulatory authorities will consider the issue of a Certificate of Suitability for connection to the supply mains under the non-declared scheme for other types and sizes as they are developed. Any application for such certification should be accompanied by a description of the flexible cord.
2 Purchasing guidelines are contained in Appendix A.
3 The AS/NZS 3350 and AS/NZS 60335 series of appliance Standards, nominate flexible cords to IEC 60227 and IEC 60245. Appendix B will facilitate the selection of cords to this Standard, which should replace the designated IEC cords.
4 AS/NZS 3008.1 should be referenced to ensure correct flexible cord selection for the intended application in respect of current ratings.
Document Type | Standard |
Status | Current |
Publisher | Standards Australia |
Committee | EL-003 |
Supersedes |
|