Categories

AS/NZS 60137:2008

AS/NZS 60137:2008

Insulated bushings for alternating voltages above 1000 V (IEC 60137, Ed. 5.0 (2003) MOD)

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

<toc>
<bookmarktable>
<bookmark index=&apos;0&apos;>
<pageno>1</pageno>
<text>AS/NZS 60137:2008 Insulated bushings for alternating voltages above 1000 V</text>
<bookmark index=&apos;1&apos;>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index=&apos;2&apos;>
<pageno>5</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index=&apos;3&apos;>
<pageno>7</pageno>
<text>INTRODUCTION</text>
</bookmark>
<bookmark index=&apos;4&apos;>
<pageno>9</pageno>
<text>1 Scope</text>
</bookmark>
<bookmark index=&apos;5&apos;>
<pageno>9</pageno>
<text>2 Normative references</text>
</bookmark>
<bookmark index=&apos;6&apos;>
<pageno>11</pageno>
<text>3 Terms and definitions</text>
</bookmark>
<bookmark index=&apos;7&apos;>
<pageno>16</pageno>
<text>4 Ratings</text>
<bookmark index=&apos;8&apos;>
<pageno>16</pageno>
<text>4.1 Standard values of highest voltage for equipment (Um)</text>
</bookmark>
<bookmark index=&apos;9&apos;>
<pageno>16</pageno>
<text>4.2 Standard values of rated current (Ir)</text>
</bookmark>
<bookmark index=&apos;10&apos;>
<pageno>17</pageno>
<text>4.3 Standard values of rated thermal short-time current (Ith)</text>
</bookmark>
<bookmark index=&apos;11&apos;>
<pageno>17</pageno>
<text>4.4 Standard values of rated dynamic current (Id)</text>
</bookmark>
<bookmark index=&apos;12&apos;>
<pageno>17</pageno>
<text>4.5 Minimum withstand values of cantilever load</text>
</bookmark>
<bookmark index=&apos;13&apos;>
<pageno>17</pageno>
<text>4.6 Angle of mounting</text>
</bookmark>
<bookmark index=&apos;14&apos;>
<pageno>17</pageno>
<text>4.7 Minimum nominal creepage distance</text>
</bookmark>
<bookmark index=&apos;15&apos;>
<pageno>18</pageno>
<text>4.8 Temperature limits and temperature rise</text>
</bookmark>
<bookmark index=&apos;16&apos;>
<pageno>18</pageno>
<text>4.9 Standard insulation levels</text>
</bookmark>
<bookmark index=&apos;17&apos;>
<pageno>19</pageno>
<text>4.10 Test tap on transformer bushings</text>
</bookmark>
</bookmark>
<bookmark index=&apos;18&apos;>
<pageno>19</pageno>
<text>5 Operating conditions</text>
<bookmark index=&apos;19&apos;>
<pageno>19</pageno>
<text>5.1 Temporary overvoltages</text>
</bookmark>
<bookmark index=&apos;20&apos;>
<pageno>19</pageno>
<text>5.2 Altitude</text>
</bookmark>
<bookmark index=&apos;21&apos;>
<pageno>20</pageno>
<text>5.3 Temperature of ambient air and immersion media</text>
</bookmark>
<bookmark index=&apos;22&apos;>
<pageno>20</pageno>
<text>5.4 Seismic conditions</text>
</bookmark>
</bookmark>
<bookmark index=&apos;23&apos;>
<pageno>20</pageno>
<text>6 Ordering information and markings</text>
<bookmark index=&apos;24&apos;>
<pageno>20</pageno>
<text>6.1 Enumeration of characteristics</text>
</bookmark>
<bookmark index=&apos;25&apos;>
<pageno>22</pageno>
<text>6.2 Markings</text>
</bookmark>
</bookmark>
<bookmark index=&apos;26&apos;>
<pageno>22</pageno>
<text>7 Test requirements</text>
<bookmark index=&apos;27&apos;>
<pageno>22</pageno>
<text>7.1 General requirements</text>
</bookmark>
<bookmark index=&apos;28&apos;>
<pageno>23</pageno>
<text>7.2 Test classification</text>
</bookmark>
<bookmark index=&apos;29&apos;>
<pageno>24</pageno>
<text>7.3 Condition of bushings during dielectric and thermal tests</text>
</bookmark>
</bookmark>
<bookmark index=&apos;30&apos;>
<pageno>24</pageno>
<text>8 Type tests</text>
<bookmark index=&apos;31&apos;>
<pageno>25</pageno>
<text>8.1 Dry or wet power-frequency voltage withstand test</text>
</bookmark>
<bookmark index=&apos;32&apos;>
<pageno>25</pageno>
<text>8.2 Dry lightning impulse voltage withstand test (BIL)</text>
</bookmark>
<bookmark index=&apos;33&apos;>
<pageno>26</pageno>
<text>8.3 Dry or wet switching impulse voltage withstand test (SIL)</text>
</bookmark>
<bookmark index=&apos;34&apos;>
<pageno>27</pageno>
<text>8.4 Thermal stability test</text>
</bookmark>
<bookmark index=&apos;35&apos;>
<pageno>28</pageno>
<text>8.5 Temperature rise test</text>
</bookmark>
<bookmark index=&apos;36&apos;>
<pageno>30</pageno>
<text>8.6 Verification of thermal short-time current withstand</text>
</bookmark>
<bookmark index=&apos;37&apos;>
<pageno>31</pageno>
<text>8.7 Cantilever load withstand test</text>
</bookmark>
<bookmark index=&apos;38&apos;>
<pageno>32</pageno>
<text>8.8 Tightness test on liquid-filled, compound-filled and liquid-insulated bushings</text>
</bookmark>
<bookmark index=&apos;39&apos;>
<pageno>32</pageno>
<text>8.9 Internal pressure test on gas-filled, gas-insulated and gas-impregnated bushings</text>
</bookmark>
<bookmark index=&apos;40&apos;>
<pageno>32</pageno>
<text>8.10 External pressure test on partly or completely gas-immersed bushings</text>
</bookmark>
<bookmark index=&apos;41&apos;>
<pageno>33</pageno>
<text>8.11 Verification of dimensions</text>
</bookmark>
</bookmark>
<bookmark index=&apos;42&apos;>
<pageno>33</pageno>
<text>9 Routine tests</text>
<bookmark index=&apos;43&apos;>
<pageno>33</pageno>
<text>9.1 Measurement of dielectric dissipation factor (tan &#948;) and capacitance at ambient temperature</text>
</bookmark>
<bookmark index=&apos;44&apos;>
<pageno>34</pageno>
<text>9.2 Dry lightning impulse voltage withstand test (BIL)</text>
</bookmark>
<bookmark index=&apos;45&apos;>
<pageno>34</pageno>
<text>9.3 Dry power-frequency voltage withstand test</text>
</bookmark>
<bookmark index=&apos;46&apos;>
<pageno>35</pageno>
<text>9.4 Measurement of partial discharge quantity</text>
</bookmark>
<bookmark index=&apos;47&apos;>
<pageno>35</pageno>
<text>9.5 Tests of tap insulation</text>
</bookmark>
<bookmark index=&apos;48&apos;>
<pageno>36</pageno>
<text>9.6 Internal pressure test on gas-filled, gas-insulated and gas-impregnated bushings</text>
</bookmark>
<bookmark index=&apos;49&apos;>
<pageno>36</pageno>
<text>9.7 Tightness test on liquid-filled, compound-filled and liquid-insulated bushings</text>
</bookmark>
<bookmark index=&apos;50&apos;>
<pageno>36</pageno>
<text>9.8 Tightness test on gas-filled, gas-insulated and gas-impregnated bushings</text>
</bookmark>
<bookmark index=&apos;51&apos;>
<pageno>37</pageno>
<text>9.9 Tightness test at the flange or other fixing device</text>
</bookmark>
<bookmark index=&apos;52&apos;>
<pageno>38</pageno>
<text>9.10 Visual inspection and dimensional check</text>
</bookmark>
</bookmark>
<bookmark index=&apos;53&apos;>
<pageno>38</pageno>
<text>10 Requirements and tests for bushings of highest voltages for equipment equal to or less than 52 kV made of ceramic, glass or inorganic materials, resin or combined insulation</text>
<bookmark index=&apos;54&apos;>
<pageno>38</pageno>
<text>10.1 Temperature requirements</text>
</bookmark>
<bookmark index=&apos;55&apos;>
<pageno>38</pageno>
<text>10.2 Level of immersion medium</text>
</bookmark>
<bookmark index=&apos;56&apos;>
<pageno>38</pageno>
<text>10.3 Markings</text>
</bookmark>
<bookmark index=&apos;57&apos;>
<pageno>39</pageno>
<text>10.4 Test requirements</text>
</bookmark>
</bookmark>
<bookmark index=&apos;58&apos;>
<pageno>50</pageno>
<text>Bibliography</text>
</bookmark>
<bookmark index=&apos;59&apos;>
<pageno>51</pageno>
<text>Annex ZA (normative) Radio influence voltage (RIV) test</text>
</bookmark>
<bookmark index=&apos;60&apos;>
<pageno>52</pageno>
<text>Annex ZZ (normative) Variations to IEC 60137, Ed. 5.0 (2003) for application in Australia and New Zealand</text>
</bookmark>
<bookmark index=&apos;61&apos;>
<pageno>55</pageno>
<text>Annex ZA (normative) Radio influence voltage (RIV) test</text>
</bookmark>
</bookmark>
</bookmarktable>
</toc>

Abstract

Specifies the characteristics and tests for insulated bushings for electrical equipment with a voltage above 1000 V a.c. and a nominal frequency in the range 15-60 Hz.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee EL-008
Supersedes
  • AS 1265-1990
  • DR 06485

Contact us