Categories

AS 5081-2008 (R2016)

AS 5081-2008 (R2016)

Hydraulically operated automatic control valves for waterworks purposes

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

<toc />

Abstract

Provides material requirements and performance tests for metallic-bodied hydraulically operated automatic control valves for waterworks purposes, together with default compliance requirements for use by manufacturers and certification bodies.
RECONFIRMATION NOTICE
Technical Committee WS-022 has reviewed the content of this publication and in
accordance with Standards Australia procedures for reconfirmation, it has been
determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the
original date of publication. Users are advised to ensure that they are using the latest
versions of such documents as appropriate, unless advised otherwise in this
Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for
reconfirmation on 23 December 2015.
The following are represented on Technical Committee WS-022:
Australian Chamber of Commerce and Industry
Australian Industry Group
Australian Stainless Steel Development Association
Australian Water Association
Engineers Australia
Institute of Instrumentation, Control & Automation Aust
Local Government New Zealand
Plastics Industry Pipe Association of Australia
Plumbing Products Industry Group
Water Services Association of Australia

Scope

This Standard specifies requirements for metallic-bodied PN 16, PN 21 and PN 35 hydraulically operated, diaphragm or piston-actuated, globe or piston-style, automatic control valves for waterworks purposes and valve sizes DN 40 to DN 900 (inclusive), suitable for, but not limited to, drinking water and recycled water, with a maximum operating temperature of 40°C.
This Standard applies to automatic control valves that operate by pressure in water mains, and controlled by hydraulic or solenoid pilot valves. Where control valves incorporate solenoid pilots, limit switches or position transmitters, low-voltage electrical power supply is required for these components.
This Standard covers the following types of automatic control valves:
(a) Fixed-outlet pressure-reducing valve.
(b) Variable-outlet pressure-reducing valve.
(c) Pressure-sustaining/relief valve.
(d) Surge-anticipating valve.
(e) Altitude valve.
(f) Float valve.
(g) Rate-of-flow control valve.
(h) Non-return valve.
)i) Solenoid-control valve.
The valves are designed for installation in a horizontal or vertical position depending on the manufacturer’s requirements, above-ground or below-ground in a drained chamber.
NOTE: Purchasing guidelines are given in Appendix B.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 03/06/2016.
This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 03/06/2016
Committee WS-022
Supersedes
  • DR 07297

Contact us