Categories

BS EN 4608-001:2019

BS EN 4608-001:2019 Aerospace series. Cable, electrical, fire resistant - Single and twisted multicore assembly, screened (braided) and jacketed. Operating temperatures between. 65 degrees C and 260 degrees C. Technical specification

standard by British-Adopted European Standard, 06/27/2019

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$67.21

$160.02

(price reduced by 58 %)

Full Description

This document specifies the required characteristics and test procedures for fire resistant or fire proofelectrical cables for use in aircraft electrical systems. They shall be operated at a rated AC voltage of600 V ac, a frequency of maximum 2 000 Hz and a long term temperature of up to 260 C (ambienttemperature plus temperatures rise in conductor).

These cables shall also maintain a specific dielectric strength when they are subjected to a flame of1 100 C after five (5) minutes (fire resistant) or 15 minutes (fire proof) exposure.

Cross References:
ISO 2574
TR 6058
EN 2234
EN 4608-002
EN 3475-100
EN 2235
EN 3838
EN 9133
EN 4608-005


All current amendments available at time of purchase are included with the purchase of this document.