AS 2629-2008
AS 2629-2008
Separable insulated connectors for power distribution systems above 1 kV
Standards Australia
Separable insulated connectors for power distribution systems above 1 kV
Standards Australia
<toc>
<bookmarktable>
<bookmark index='0'>
<pageno>1</pageno>
<text>AS 2629-2008 SEPARABLE INSULATED CONNECTORS FOR POWER DISTRIBUTION SYSTEMS ABOVE 1 KV</text>
<bookmark index='1'>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index='2'>
<pageno>5</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index='3'>
<pageno>6</pageno>
<text>SECTION 1 SCOPE AND GENERAL</text>
<bookmark index='4'>
<pageno>6</pageno>
<text>1.1 SCOPE</text>
</bookmark>
<bookmark index='5'>
<pageno>6</pageno>
<text>1.2 REFERENCED DOCUMENTS</text>
</bookmark>
<bookmark index='6'>
<pageno>6</pageno>
<text>1.3 SERVICE CONDITIONS</text>
<bookmark index='7'>
<pageno>6</pageno>
<text>1.3.1 Normal service conditions</text>
</bookmark>
<bookmark index='8'>
<pageno>7</pageno>
<text>1.3.2 Special service conditions</text>
</bookmark>
</bookmark>
</bookmark>
<bookmark index='9'>
<pageno>8</pageno>
<text>SECTION 2 DEFINITIONS</text>
<bookmark index='10'>
<pageno>8</pageno>
<text>2.1 APPLICATION OF SECTION</text>
</bookmark>
<bookmark index='11'>
<pageno>8</pageno>
<text>2.2 GENERAL TERMS</text>
<bookmark index='12'>
<pageno>8</pageno>
<text>2.2.1 Dead-break connector</text>
</bookmark>
<bookmark index='13'>
<pageno>8</pageno>
<text>2.2.2 Load-break connector</text>
</bookmark>
<bookmark index='14'>
<pageno>8</pageno>
<text>2.2.3 Operating interface</text>
</bookmark>
<bookmark index='15'>
<pageno>8</pageno>
<text>2.2.4 Separable insulated connector (hereinafter referred to as connector)</text>
</bookmark>
</bookmark>
<bookmark index='16'>
<pageno>8</pageno>
<text>2.3 HARDWARE ITEMS</text>
<bookmark index='17'>
<pageno>8</pageno>
<text>2.3.1 Bushing insert</text>
</bookmark>
<bookmark index='18'>
<pageno>8</pageno>
<text>2.3.2 Bushing well</text>
</bookmark>
<bookmark index='19'>
<pageno>8</pageno>
<text>2.3.3 Earthing (grounding) bushing</text>
</bookmark>
<bookmark index='20'>
<pageno>8</pageno>
<text>2.3.4 Earthing elbow</text>
</bookmark>
<bookmark index='21'>
<pageno>8</pageno>
<text>2.3.5 Earthing rod</text>
</bookmark>
<bookmark index='22'>
<pageno>8</pageno>
<text>2.3.6 Elbow</text>
</bookmark>
<bookmark index='23'>
<pageno>9</pageno>
<text>2.3.7 Feed-through device</text>
</bookmark>
<bookmark index='24'>
<pageno>9</pageno>
<text>2.3.8 Hold-down bail</text>
</bookmark>
<bookmark index='25'>
<pageno>9</pageno>
<text>2.3.9 Insulated parking bushing</text>
</bookmark>
<bookmark index='26'>
<pageno>9</pageno>
<text>2.3.10 Insulated cap</text>
</bookmark>
<bookmark index='27'>
<pageno>9</pageno>
<text>2.3.11 Integral bushing</text>
</bookmark>
<bookmark index='28'>
<pageno>9</pageno>
<text>2.3.12 Parking stand</text>
</bookmark>
<bookmark index='29'>
<pageno>9</pageno>
<text>2.3.13 Plug</text>
</bookmark>
<bookmark index='30'>
<pageno>9</pageno>
<text>2.3.14 Test point</text>
</bookmark>
</bookmark>
<bookmark index='31'>
<pageno>9</pageno>
<text>2.4 ELECTRICAL CHARACTERISTICS</text>
<bookmark index='32'>
<pageno>9</pageno>
<text>2.4.1 Partial discharge (corona) extinction voltage</text>
</bookmark>
<bookmark index='33'>
<pageno>9</pageno>
<text>2.4.2 Rated short-circuit making current</text>
</bookmark>
<bookmark index='34'>
<pageno>9</pageno>
<text>2.4.3 Rated lightning impulse withstand voltage</text>
</bookmark>
<bookmark index='35'>
<pageno>9</pageno>
<text>2.4.4 Rated normal current</text>
</bookmark>
<bookmark index='36'>
<pageno>9</pageno>
<text>2.4.5 Rated (short duration) power frequency withstand voltage</text>
</bookmark>
<bookmark index='37'>
<pageno>10</pageno>
<text>2.4.6 Rated short-time withstand current</text>
</bookmark>
<bookmark index='38'>
<pageno>10</pageno>
<text>2.4.7 Rated switching current</text>
</bookmark>
<bookmark index='39'>
<pageno>10</pageno>
<text>2.4.8 Rated voltage</text>
</bookmark>
</bookmark>
</bookmark>
<bookmark index='40'>
<pageno>15</pageno>
<text>SECTION 3 RATINGS</text>
<bookmark index='41'>
<pageno>15</pageno>
<text>3.1 VOLTAGE RATINGS</text>
<bookmark index='42'>
<pageno>15</pageno>
<text>3.1.1 Rated voltage</text>
</bookmark>
<bookmark index='43'>
<pageno>15</pageno>
<text>3.1.2 Insulation level</text>
</bookmark>
<bookmark index='44'>
<pageno>15</pageno>
<text>3.1.3 Partial discharge extinction voltage</text>
</bookmark>
</bookmark>
<bookmark index='45'>
<pageno>15</pageno>
<text>3.2 RATED FREQUENCY</text>
</bookmark>
<bookmark index='46'>
<pageno>15</pageno>
<text>3.3 CURRENT RATINGS</text>
<bookmark index='47'>
<pageno>15</pageno>
<text>3.3.1 Normal current</text>
</bookmark>
<bookmark index='48'>
<pageno>15</pageno>
<text>3.3.2 Switching current (load-break connectors)</text>
</bookmark>
<bookmark index='49'>
<pageno>15</pageno>
<text>3.3.3 Short-time withstand current</text>
</bookmark>
<bookmark index='50'>
<pageno>16</pageno>
<text>3.3.4 Short-circuit making current (load-break connectors)</text>
</bookmark>
</bookmark>
</bookmark>
<bookmark index='51'>
<pageno>17</pageno>
<text>SECTION 4 DESIGN, CONSTRUCTION AND MARKING</text>
<bookmark index='52'>
<pageno>17</pageno>
<text>4.1 DESIGN</text>
</bookmark>
<bookmark index='53'>
<pageno>17</pageno>
<text>4.2 INTERCHANGEABILITY</text>
</bookmark>
<bookmark index='54'>
<pageno>17</pageno>
<text>4.3 OPERATING MEANS</text>
</bookmark>
<bookmark index='55'>
<pageno>17</pageno>
<text>4.4 SHIELDING</text>
</bookmark>
<bookmark index='56'>
<pageno>17</pageno>
<text>4.5 TEST POINTS</text>
<bookmark index='57'>
<pageno>17</pageno>
<text>4.5.1 Requirements</text>
</bookmark>
<bookmark index='58'>
<pageno>17</pageno>
<text>4.5.2 Capacitance</text>
</bookmark>
</bookmark>
<bookmark index='59'>
<pageno>17</pageno>
<text>4.6 HOLD-DOWN BAILS</text>
</bookmark>
<bookmark index='60'>
<pageno>18</pageno>
<text>4.7 MARKING</text>
</bookmark>
</bookmark>
<bookmark index='61'>
<pageno>30</pageno>
<text>SECTION 5 PERFORMANCE</text>
<bookmark index='62'>
<pageno>30</pageno>
<text>5.1 BEHAVIOUR ON TEST AND IN SERVICE</text>
<bookmark index='63'>
<pageno>30</pageno>
<text>5.1.1 Current-carrying performance</text>
</bookmark>
<bookmark index='64'>
<pageno>30</pageno>
<text>5.1.2 Switching current performance</text>
</bookmark>
<bookmark index='65'>
<pageno>30</pageno>
<text>5.1.3 Short-circuit making current performance</text>
</bookmark>
<bookmark index='66'>
<pageno>30</pageno>
<text>5.1.4 Operating forces and torques</text>
</bookmark>
</bookmark>
<bookmark index='67'>
<pageno>30</pageno>
<text>5.2 OPERATING TEMPERATURE OF MATERIALS</text>
</bookmark>
</bookmark>
<bookmark index='68'>
<pageno>31</pageno>
<text>SECTION 6 CLASSIFICATION OF TESTS</text>
<bookmark index='69'>
<pageno>31</pageno>
<text>6.1 TYPE TESTS</text>
<bookmark index='70'>
<pageno>31</pageno>
<text>6.1.1 Purpose</text>
</bookmark>
<bookmark index='71'>
<pageno>31</pageno>
<text>6.1.2 Connectors tested</text>
</bookmark>
<bookmark index='72'>
<pageno>31</pageno>
<text>6.1.3 Test report</text>
</bookmark>
<bookmark index='73'>
<pageno>31</pageno>
<text>6.1.4 Repeat tests</text>
</bookmark>
<bookmark index='74'>
<pageno>31</pageno>
<text>6.1.5 Test records</text>
</bookmark>
</bookmark>
<bookmark index='75'>
<pageno>31</pageno>
<text>6.2 ROUTINE TESTS</text>
</bookmark>
<bookmark index='76'>
<pageno>31</pageno>
<text>6.3 TESTS AT SITE</text>
<bookmark index='77'>
<pageno>31</pageno>
<text>6.3.1 General</text>
</bookmark>
<bookmark index='78'>
<pageno>32</pageno>
<text>6.3.2 Power-frequency voltage tests</text>
</bookmark>
<bookmark index='79'>
<pageno>32</pageno>
<text>6.3.3 D.C. voltage tests</text>
</bookmark>
<bookmark index='80'>
<pageno>32</pageno>
<text>6.3.4 Other tests</text>
</bookmark>
</bookmark>
</bookmark>
<bookmark index='81'>
<pageno>34</pageno>
<text>SECTION 7 DETAILS OF TYPE TESTS</text>
<bookmark index='82'>
<pageno>34</pageno>
<text>7.1 DIELECTRIC TESTS</text>
<bookmark index='83'>
<pageno>34</pageno>
<text>7.1.1 Purpose</text>
</bookmark>
<bookmark index='84'>
<pageno>34</pageno>
<text>7.1.2 Mounting preparation</text>
</bookmark>
<bookmark index='85'>
<pageno>34</pageno>
<text>7.1.3 Requirements</text>
</bookmark>
<bookmark index='86'>
<pageno>34</pageno>
<text>7.1.4 Power frequency voltage</text>
</bookmark>
<bookmark index='87'>
<pageno>34</pageno>
<text>7.1.5 Partial discharge</text>
</bookmark>
<bookmark index='88'>
<pageno>34</pageno>
<text>7.1.6 D.C. voltage</text>
</bookmark>
<bookmark index='89'>
<pageno>34</pageno>
<text>7.1.7 Impulse</text>
</bookmark>
</bookmark>
<bookmark index='90'>
<pageno>35</pageno>
<text>7.2 SHORT-CIRCUIT CURRENT-CARRYING CAPABILITY TEST</text>
<bookmark index='91'>
<pageno>35</pageno>
<text>7.2.1 Purpose</text>
</bookmark>
<bookmark index='92'>
<pageno>35</pageno>
<text>7.2.2 Mounting preparation</text>
</bookmark>
<bookmark index='93'>
<pageno>35</pageno>
<text>7.2.3 Requirements</text>
</bookmark>
</bookmark>
<bookmark index='94'>
<pageno>35</pageno>
<text>7.3 SWITCHING CURRENT TESTS (Applicable to load-break connectors only)</text>
<bookmark index='95'>
<pageno>35</pageno>
<text>7.3.1 Purpose</text>
</bookmark>
<bookmark index='96'>
<pageno>35</pageno>
<text>7.3.2 Mounting preparation</text>
</bookmark>
<bookmark index='97'>
<pageno>36</pageno>
<text>7.3.3 Requirements</text>
</bookmark>
<bookmark index='98'>
<pageno>36</pageno>
<text>7.3.4 Electrical circuit conditions</text>
</bookmark>
</bookmark>
<bookmark index='99'>
<pageno>37</pageno>
<text>7.4 SHORT-CIRCUIT MAKING CURRENT TEST (Applicable to load-break connectors only)</text>
<bookmark index='100'>
<pageno>37</pageno>
<text>7.4.1 Purpose</text>
</bookmark>
<bookmark index='101'>
<pageno>37</pageno>
<text>7.4.2 Mounting preparation</text>
</bookmark>
<bookmark index='102'>
<pageno>37</pageno>
<text>7.4.3 Requirements</text>
</bookmark>
</bookmark>
<bookmark index='103'>
<pageno>37</pageno>
<text>7.5 CONNECTOR ELBOW DISTORTION TEST FOR OFF-AXIS FORCE (Applicable only to elbows of the non-bolted type).</text>
<bookmark index='104'>
<pageno>37</pageno>
<text>7.5.1 Purpose</text>
</bookmark>
<bookmark index='105'>
<pageno>37</pageno>
<text>7.5.2 Preparation for test</text>
</bookmark>
<bookmark index='106'>
<pageno>40</pageno>
<text>7.5.3 Off-axis operating tests</text>
</bookmark>
<bookmark index='107'>
<pageno>40</pageno>
<text>7.5.4 Verification of results</text>
</bookmark>
</bookmark>
<bookmark index='108'>
<pageno>40</pageno>
<text>7.6 CURRENT CYCLING TEST</text>
<bookmark index='109'>
<pageno>40</pageno>
<text>7.6.1 Purpose</text>
</bookmark>
<bookmark index='110'>
<pageno>41</pageno>
<text>7.6.2 Preparation for test</text>
</bookmark>
<bookmark index='111'>
<pageno>41</pageno>
<text>7.6.3 Requirements</text>
</bookmark>
<bookmark index='112'>
<pageno>41</pageno>
<text>7.6.4 Verification of results</text>
</bookmark>
</bookmark>
<bookmark index='113'>
<pageno>41</pageno>
<text>7.7 CABLE PULL-OUT TEST</text>
<bookmark index='114'>
<pageno>41</pageno>
<text>7.7.1 Purpose</text>
</bookmark>
<bookmark index='115'>
<pageno>41</pageno>
<text>7.7.2 Requirements</text>
</bookmark>
</bookmark>
<bookmark index='116'>
<pageno>42</pageno>
<text>7.8 OPERATING FORCE TEST</text>
<bookmark index='117'>
<pageno>42</pageno>
<text>7.8.1 Purpose</text>
</bookmark>
<bookmark index='118'>
<pageno>42</pageno>
<text>7.8.2 Requirements</text>
</bookmark>
</bookmark>
<bookmark index='119'>
<pageno>42</pageno>
<text>7.9 OPERATING EYE TEST</text>
<bookmark index='120'>
<pageno>42</pageno>
<text>7.9.1 Purpose</text>
</bookmark>
<bookmark index='121'>
<pageno>42</pageno>
<text>7.9.2 Test method and requirements</text>
</bookmark>
</bookmark>
<bookmark index='122'>
<pageno>42</pageno>
<text>7.10 TEST POINT CAP MECHANICAL TEST</text>
<bookmark index='123'>
<pageno>42</pageno>
<text>7.10.1 Purpose</text>
</bookmark>
<bookmark index='124'>
<pageno>42</pageno>
<text>7.10.2 Removal force</text>
</bookmark>
<bookmark index='125'>
<pageno>42</pageno>
<text>7.10.3 Operating force withstand</text>
</bookmark>
</bookmark>
<bookmark index='126'>
<pageno>43</pageno>
<text>7.11 TEST POINT ELECTRICAL TESTS</text>
<bookmark index='127'>
<pageno>43</pageno>
<text>7.11.1 Purpose</text>
</bookmark>
<bookmark index='128'>
<pageno>43</pageno>
<text>7.11.2 Capacitance test</text>
</bookmark>
<bookmark index='129'>
<pageno>43</pageno>
<text>7.11.3 Voltage indication test</text>
</bookmark>
</bookmark>
<bookmark index='130'>
<pageno>43</pageno>
<text>7.12 SHIELDING TEST</text>
<bookmark index='131'>
<pageno>43</pageno>
<text>7.12.1 Purpose</text>
</bookmark>
<bookmark index='132'>
<pageno>43</pageno>
<text>7.12.2 Test procedure</text>
</bookmark>
</bookmark>
<bookmark index='133'>
<pageno>43</pageno>
<text>7.13 ACCELERATED SEALING LIFE TEST</text>
<bookmark index='134'>
<pageno>43</pageno>
<text>7.13.1 Purpose</text>
</bookmark>
<bookmark index='135'>
<pageno>43</pageno>
<text>7.13.2 Sequence</text>
</bookmark>
<bookmark index='136'>
<pageno>43</pageno>
<text>7.13.3 Thermal ageing test</text>
</bookmark>
<bookmark index='137'>
<pageno>44</pageno>
<text>7.13.4 Heating and immersion cycles</text>
</bookmark>
<bookmark index='138'>
<pageno>44</pageno>
<text>7.13.5 Verification of results</text>
</bookmark>
</bookmark>
</bookmark>
</bookmark>
</bookmarktable>
</toc>
This Standard applies a method of connection and switching of transformers and other electrical equipment in distribution systems using special flexible cable connectors.
This Standard specifies requirements for load-break and dead-break separable insulated connectors and ancillary equipment for use on power distribution systems at alternating voltages above 1 kV.
The Standard applies to separable insulated connectors rated at not more than 1250 A.
NOTE: Load-break connectors are available only for the lower current ratings. The purchaser should obtain information from manufacturers on available current ratings.
Document Type | Standard |
Status | Current |
Publisher | Standards Australia |
Committee | EL-007 |
Supersedes |
|