Categories

AS/NZS 4776.1.2:2008

AS/NZS 4776.1.2:2008

Liquid-chilling packages using the vapour compression cycle Method of rating and testing for performance - Testing

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

<toc>
<bookmarktable>
<bookmark index=&apos;0&apos;>
<pageno>1</pageno>
<text>AS/NZS 4776.1.2:2008 LIQUID-CHILLING PACKAGES USING THE VAPOUR COMPRESSION CYCLE - METHOD OF RATING AND TESTING FOR...</text>
<bookmark index=&apos;1&apos;>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index=&apos;2&apos;>
<pageno>5</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index=&apos;3&apos;>
<pageno>6</pageno>
<text>1 SCOPE</text>
</bookmark>
<bookmark index=&apos;4&apos;>
<pageno>6</pageno>
<text>2 OBJECTIVE</text>
</bookmark>
<bookmark index=&apos;5&apos;>
<pageno>6</pageno>
<text>3 NORMATIVE REFERENCE</text>
</bookmark>
<bookmark index=&apos;6&apos;>
<pageno>6</pageno>
<text>4 DEFINITIONS</text>
</bookmark>
<bookmark index=&apos;7&apos;>
<pageno>6</pageno>
<text>5 BASIC PRINCIPLES</text>
<bookmark index=&apos;8&apos;>
<pageno>6</pageno>
<text>5.1 Cooling capacity</text>
</bookmark>
<bookmark index=&apos;9&apos;>
<pageno>7</pageno>
<text>5.2 Water-cooled condenser heat rejection</text>
</bookmark>
</bookmark>
<bookmark index=&apos;10&apos;>
<pageno>7</pageno>
<text>6 TEST METHOD</text>
<bookmark index=&apos;11&apos;>
<pageno>7</pageno>
<text>6.1 General</text>
</bookmark>
<bookmark index=&apos;12&apos;>
<pageno>7</pageno>
<text>6.2 Conditions of heat transfer surfaces</text>
</bookmark>
<bookmark index=&apos;13&apos;>
<pageno>7</pageno>
<text>6.3 Measurements</text>
</bookmark>
<bookmark index=&apos;14&apos;>
<pageno>7</pageno>
<text>6.4 Units with integral pumps</text>
</bookmark>
</bookmark>
<bookmark index=&apos;15&apos;>
<pageno>8</pageno>
<text>7 TEST VERIFICATION</text>
<bookmark index=&apos;16&apos;>
<pageno>8</pageno>
<text>7.1 General</text>
</bookmark>
<bookmark index=&apos;17&apos;>
<pageno>8</pageno>
<text>7.2 Heat balance substantiating test (calculation of the heat balance)</text>
</bookmark>
<bookmark index=&apos;18&apos;>
<pageno>8</pageno>
<text>7.3 Percentage heat balance</text>
</bookmark>
</bookmark>
<bookmark index=&apos;19&apos;>
<pageno>8</pageno>
<text>8 INSTRUMENTATION-ACCURACY</text>
</bookmark>
<bookmark index=&apos;20&apos;>
<pageno>9</pageno>
<text>9 TEST PROCEDURE</text>
<bookmark index=&apos;21&apos;>
<pageno>9</pageno>
<text>9.1 General</text>
</bookmark>
<bookmark index=&apos;22&apos;>
<pageno>9</pageno>
<text>9.2 Steady-state conditions</text>
</bookmark>
<bookmark index=&apos;23&apos;>
<pageno>9</pageno>
<text>9.3 Output measurement of cooling capacity and power input</text>
</bookmark>
<bookmark index=&apos;24&apos;>
<pageno>10</pageno>
<text>9.4 Calculation of results</text>
<bookmark index=&apos;25&apos;>
<pageno>10</pageno>
<text>9.4.1 Cooling capacity and heat rejection capacity</text>
</bookmark>
<bookmark index=&apos;26&apos;>
<pageno>10</pageno>
<text>9.4.2 Power consumption</text>
</bookmark>
</bookmark>
</bookmark>
<bookmark index=&apos;27&apos;>
<pageno>10</pageno>
<text>10 DATA TO BE RECORDED</text>
<bookmark index=&apos;28&apos;>
<pageno>10</pageno>
<text>10.1 Measurement data</text>
</bookmark>
<bookmark index=&apos;29&apos;>
<pageno>11</pageno>
<text>10.2 Auxiliary information to be recorded</text>
</bookmark>
</bookmark>
<bookmark index=&apos;30&apos;>
<pageno>11</pageno>
<text>11 FOULING CONSIDERATIONS FOR TESTING</text>
</bookmark>
<bookmark index=&apos;31&apos;>
<pageno>12</pageno>
<text>12 VERIFICATION TEST TOLERANCE ON HEAT BALANCE</text>
</bookmark>
<bookmark index=&apos;32&apos;>
<pageno>13</pageno>
<text>APPENDIX A - CONCURRENT REDUNDANT VERIFICATION TEST FOR AIR-COOLED OR EVAPORATIVELY COOLED CONDENSER UNITS</text>
<bookmark index=&apos;33&apos;>
<pageno>13</pageno>
<text>A1 GENERAL</text>
</bookmark>
<bookmark index=&apos;34&apos;>
<pageno>13</pageno>
<text>A2 CAPACITY CALCULATION METHOD</text>
</bookmark>
<bookmark index=&apos;35&apos;>
<pageno>13</pageno>
<text>A3 POWER CALCULATION METHOD</text>
</bookmark>
<bookmark index=&apos;36&apos;>
<pageno>13</pageno>
<text>A4 EFFICIENCY CALCULATION METHOD</text>
</bookmark>
</bookmark>
<bookmark index=&apos;37&apos;>
<pageno>14</pageno>
<text>APPENDIX B - METHOD FOR SIMULATING THE FOULING FACTOR ALLOWANCE</text>
<bookmark index=&apos;38&apos;>
<pageno>14</pageno>
<text>B1 SCOPE</text>
</bookmark>
<bookmark index=&apos;39&apos;>
<pageno>14</pageno>
<text>B2 FOULING ALLOWANCE PROCEDURE</text>
<bookmark index=&apos;40&apos;>
<pageno>14</pageno>
<text>B2.1 Derivation of log mean temperature difference (LMTD)</text>
</bookmark>
<bookmark index=&apos;41&apos;>
<pageno>14</pageno>
<text>B2.2 Derivation of incremental log mean temperature difference (ILMTD)</text>
</bookmark>
<bookmark index=&apos;42&apos;>
<pageno>15</pageno>
<text>B2.3 Example-Condenser fouling</text>
</bookmark>
</bookmark>
<bookmark index=&apos;43&apos;>
<pageno>15</pageno>
<text>B3 SYMBOLS AND SUBSCRIPTS</text>
</bookmark>
</bookmark>
</bookmark>
</bookmarktable>
</toc>

Abstract

Prescribes the method of testing liquid-chilling packages using the vapour compression cycle to determine the capacity, power and efficiency of equipment under a specific set of conditions.

Scope

This Standard covers liquid-chilling packages within the scope of AS/NZS 4776.1.1.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee ME-086
Supersedes
  • DR 07277

Contact us