Categories

IEC 61010-2-012 Ed. 2.0 b:2019

IEC 61010-2-012 Ed. 2.0 b:2019 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-012: Particular requirements for climatic and environmental testing and other temperature conditioning equipment

standard by International Electrotechnical Commission, 04/01/2019

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$147.84

$352.00

(price reduced by 58 %)

Full Description

IEC 61010-2-012:2019 specifies safety requirements for electrical equipment and its accessories within the categories a) through c), wherever it is intended to be used, whenever that equipment incorporates one or more of the following characteristics: A refrigerating system that is acted on or impacted by an integral heating function such that the combined heating and refrigerating system generates additional and/or more severe hazards than those for the two systems if treated separately. The materials being treated in the intended application introduce significant heat into the refrigerating system, so that the refrigerating system in the application yields additional and/or more severe hazards than those for the refrigerating system if operated at the maximum rated ambient temperature alone. An irradiation function for the materials being treated presenting additional hazards. A function to expose the materials being treated to excessive humidity, carbon dioxide, salt mist, or other substances which can result in additional hazards. A function of mechanical movement presenting additional hazards. Provision for an operator to walk in to the operating area to load or unload the materials being treated.It has the status of a group safety publication in accordance with IEC Guide 104.
This second edition cancels and replaces the first edition published in 2016. This edition constitutes a technical revision.

This edition includes the following significant technical changes with respect to the previous edition: a) alignment with changes introduced by Amendment 1 of IEC 61010-1:2010; b) changes related to the use of small capitals for defined terms only; c) clarifications for cooling tests in 4.4.2.10; d) requirements for overtemperature protection in 10.101, including deletion of the second part of the sentence in item b), and the deletion of item c); e) changes pertaining to the accurate employment of terms "temperature", "operating temperature", "working temperature", "application temperature", "room temperature" and "ambient temperature" in 3.5.104, 3.5.105, 4.3.1, 4.3.2, 5.4.2, 8.2.1, 8.2.2, 11.7.2.101.2, 11.7.2.101.3, 13.2.102, 14.102, 15.101, 15.102, 15.103, Introduction and many other locations. For the purpose of clarification, the definition of 3.5.114, controlled temperature, is added.

Contact us