Categories

IEEE 1204-1997

IEEE 1204-1997 IEEE Guide for Planning DC Links Terminating at AC Locations Having Low Short-Circuit Capacities

standard by IEEE, 01/01/1997

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$67.32

$153.00

(price reduced by 56 %)

Full Description

Scope

Part I of the guide discusses the effects of various aspects of the ac/dc interactions on the design and performance of dc schemes where the ac system appears as a high impedance at the ac/dc interface bus; i.e., low and very low short-circuit (short-circuit ratio [SCR]) conditions. AC systems having zero or inadequate mechanical rotational inertia, such as island schemes with no or with limited local generation, are also considered. Environmental, siting, and construction issues are not addressed. General issues, such as steady-state reactive compensation and ac and dc filter requirements, are not in the scope of this guide, but would be included in a complete study for a particular dc scheme design. In order to assist those not familiar with dc transmission and convertors, a brief description of basic rectifier and inverter operation is given in Annex A of Part I.Part II of this guide, which is bound together with Part I, considers how the ac/dc interaction phenomena described in Part I should be taken into account in the planning and the preliminary design of ac/dc systems having low or very low SCR values.

Purpose

The purpose of Part I of this guide is to address factors required to be considered in the design of dc transmission schemes in the context of system interactions resulting from dc links terminating at ac system locations having low short-circuit capacities relative to dc power infeed and for cases where the inertia of the ac system is too low for satisfactory operation. The following ac/dc interactions are considered: power, voltage, and frequency instabilities; harmonic resonance-related instabilities; subsynchronous torsional interactions; temporary overvoltages; and recoveries from ac and dc faults.

Abstract

New IEEE Standard - Inactive-Withdrawn.Guidance on the planning and design of dc links terminating at ac system locations having low Guidance on the planning and design of dc links terminating at ac system locations having lowshort-circuit capacities relative to the dc power infeed is provided in this guide. This guide is limited to the aspects of interactions between ac and dc systems that result from the fact that the ac system is weak compared to the power of the dc link (i.e., ac system appears as a high impedance at the ac/dc interface bus). This guide contains two parts: Part I, AC/DC Interaction Phenomena, classifies the strength of the ac/dc system, provides information about interactions between ac and dc systems, and gives guidance on design and performance; and Part II, Planning Guidelines, considers the impact of ac/dc system interactions and their mitigation on economics and overall system performance and discusses the studies that need to be performed.

Contact us