Categories

IEEE 484-2002

IEEE 484-2002 IEEE Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications

standard by IEEE, 02/12/2003

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$40.48

$92.00

(price reduced by 56 %)

Full Description

Scope

This recommended practice provides recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of vented lead-acid batteries. Required safety practices are also included. This recommended practice applies to all stationary applications. However, specific applications, such as emergency lighting units and semiportable equipment, and alternate energy applications, may have other appropriate practices and are beyond the scope of this recommended practice. The portions of this recommended practice that specifically relate to personnel safety are mandatory instructions and are designated by the word shall; all other portions are recommended practices and are designated by the word should. Sizing, maintenance, capacity testing, charging equipment, dry charged cells, and consideration of other types of batteries are beyond the scope of this recommended practice.

Purpose

As part of its 5-year life cycle, the Recommended Practice should be updated to be consistent with similar Recommended Practices. Recent industry practices and developments are to be incorporated.

Abstract

Revision Standard - Active.This standard provides general requirements, direction, and methods for qualifying Class1E electric cables, field splices, factory splices, and factory rework for service in nuclear power generating stations. Categories of cables covered are those used for power, control, and instrumentation services, including signal and communication cables. Field cables, wires, and splices are within the scope of this standard. Cables, wires, and splices within or integral to other devices (e.g., instruments, panels, motors, etc.) should be qualified using the requirements in the applicable device standard or IEEE Std 323TM-1983, as appropriate. However, this standard's requirements may be applied to the wire and cable within these devices.

Contact us