Categories

IEEE C95.1-2345-2014

IEEE C95.1-2345-2014 IEEE Standard for Military Workplaces--Force Health Protection Regarding Personnel Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz

standard by IEEE, 05/30/2014

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$52.80

$120.00

(price reduced by 56 %)

Full Description

Scope

This standard provides recommendations to protect personnel in military environments against established adverse health effects associated with exposure to electric, magnetic, and electromagnetic fields, induced and contact current, and contact and arcing voltages over the frequency range of 0 Hz to 300 GHz. The recommendations, expressed as dosimetric reference limits (DRLs) and exposure reference levels (ERLs), incorporate safety factors that address uncertainties such as uncertainties in the experimental data, measurement uncertainties, and differences in threshold variability between individuals, so as to establish an appropriate margin of safety. The DRLs are expressed in terms of in situ electric field strength, specific absorption rate (SAR), and incident power density. The ERLs are expressed in terms of environmental exposure fields and power densities. In the case of contact current, however, only ERLs are provided. The DRLs and ERLs are intended to protect against established adverse human health effects associated with electrostimulation of tissue and partial and whole-body heating, but may not protect against electromagnetic interference (EMI) with implanted medical devices. This standard does not apply to exposure of informed volunteers in medical or scientific research studies subject to approval by institutional review boards for the use of human subjects, nor does it include exposure assessmenttechniques, risk management/safety program procedures, warning sign design, procedures for medical treatment of suspected overexposures, nor assessment of hazards associated with exposure of ordnance, fuel, or electro-explosive devices.

Purpose

The purpose of this standard is to provide science-based exposure limits for incorporation into a safety and occupational health (SOH) risk management program to protect personnel in a military workplace against established adverse health effects associated with exposure to electric, magnetic and electromagnetic fields, induced and contact currents, and contact (and arcing) voltages over the frequency range of 0 Hz to 300 GHz.

Abstract

New IEEE Standard - Active.Recommendations to protect personnel in military environments against established adverse health effects associated with exposure to electric, magnetic, and electromagnetic fields, induced and contact current, and contact and arcing voltages over the frequency range of 0 Hz to 300 GHz are provided in this standard. IEEE Std C95.1-2345(TM) was developed to replace NorthAtlantic Treaty Organization (NATO) Standardization Agreement (STANAG) 2345 (Edition 3), Evaluation and Control of Personnel Exposure to Radio Frequency Fields--3 kHz to 300 GHz, (13 February 2003). (The PDF of this standard is available at no charge at the compliments of the United States Navy, United States Air Force, and United States Army and the IEEEGETC95 program located at http://standards.ieee.org/getieee/C95/download/C95.1-2345-2014.pdf)

Contact us