Categories

AS/NZS 61000.4.15:2012

AS/NZS 61000.4.15:2012

Electromagnetic compatibility (EMC) Testing and measurement techniques - Flickermeter - Functional and design specifications

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Abstract

Adopts IEC 61000-4-15, Ed.2.0 to provide basic information for the design and the instrumentation of an analogue or digital flicker measuring apparatus.

Scope

This part of IEC 61000 gives a functional and design specification for flicker measuring
apparatus intended to indicate the correct flicker perception level for all practical voltage fluctuation waveforms. Information is presented to enable such an instrument to be
constructed. A method is given for the evaluation of flicker severity on the basis of the output of flickermeters complying with this standard.
The flickermeter specifications in this part of IEC 61000 relate only to measurements of 120 V
and 230 V, 50 Hz and 60 Hz inputs. Characteristics of some incandescent lamps for other voltages are sufficiently similar to the values in Table 1 and Table 2, that the use of a
correction factor can be applied for those other voltages. Some of these correction factors are
provided in the Annex B. Detailed specifications for voltages and frequencies other than those
given above, remain under consideration.
The object of this part of IEC 61000 is to provide basic information for the design and the
instrumentation of an analogue or digital flicker measuring apparatus. It does not give
tolerance limit values of flicker severity.